# Confined Spaces in Construction

Source: https://usi.how/osha-10-construction/confined-spaces-in-construction

## Understanding Confined Spaces

### What Is a Confined Space?

A confined space has three key characteristics:

- Large enough for a worker to enter fully and perform work
- Not designed for continuous occupancy
- Has limited or restricted means of entry or exit
 

Examples in construction include:

- Manholes
- Sewers
- Storm drains
- Water mains
- Crawl spaces
- Attics
- HVAC ducts
- Storage tanks
- Pits and excavations
- Utility vaults
 

### Permit-Required Confined Spaces

A confined space becomes permit-required when it has one or more of these hazards:

- Contains or has potential to contain a hazardous atmosphere
- Contains material that could engulf an entrant
- Has an internal configuration that could trap or asphyxiate an entrant
- Contains any other recognized serious safety or health hazard
 

### Difference Between General Industry and Construction Standards

- Construction standard (29 CFR 1926 Subpart AA) applies to new construction, alteration, and repair
- More detailed coordination requirements for multiple employers
- More specific provisions for controlling hazards
- Different requirements for residential construction
 

## Identifying and Evaluating Confined Spaces

### Competent Person Responsibilities

- Must identify all confined spaces at worksite before work begins
- Determine if spaces are permit-required
- Test and monitor the space as needed
- Evaluate hazards of the space
- Specify necessary precautions
- Verify testing is conducted by qualified person
 

### Common Confined Space Hazards

#### Atmospheric Hazards

- Oxygen deficiency (less than 19.5%)
- Oxygen enrichment (more than 23.5%)
- Flammable gases or vapors
- Toxic air contaminants
- Carbon monoxide
- Hydrogen sulfide
- Methane
 

#### Physical Hazards

- Engulfment by materials
- Entrapment by converging walls
- Mechanical hazards (moving parts)
- Electrical hazards
- Falling objects
- Extreme temperatures
- Noise and vibration
- Limited visibility
 

#### Other Hazards

- Limited communication
- Difficult rescue
- Structural collapse
- Uncontrolled energy sources
- Insects, animals, or reptiles
- Bacterial hazards from sewage
- Drowning
 

### Testing and Monitoring

- Test atmosphere in this order: 
    1. Oxygen content
    2. Flammable gases and vapors
    3. Toxic air contaminants
- Test at various levels (top, middle, bottom)
- Test before each entry
- Continuous monitoring during work
- Calibrate instruments according to manufacturer specifications
- Document all test results
 

## Entry Procedures and Requirements

### Permit System

- Written permit signed by entry supervisor
- Identifies the space to be entered
- Purpose and date of entry
- Duration of authorization
- List of authorized entrants and attendants
- Hazards of the space
- Control measures to eliminate or control hazards
- Acceptable entry conditions
- Testing results with tester's initials
- Rescue procedures and equipment
- Communication procedures
 

### Roles and Responsibilities

#### Entry Supervisor

- Knows hazards and symptoms of exposure
- Verifies tests, procedures, and equipment
- Terminates entry as needed
- Verifies rescue services are available
- Removes unauthorized individuals
- Ensures acceptable conditions maintained
 

#### Authorized Entrants

- Know hazards, including signs, symptoms, and consequences
- Use equipment properly
- Communicate with attendant
- Alert attendant of hazards
- Exit immediately when ordered or upon recognizing danger
 

#### Attendant

- Remains outside space during entry
- Maintains count of entrants
- Monitors conditions inside and outside space
- Communicates with entrants
- Summons rescue when needed
- Prevents unauthorized entry
- Performs non-entry rescue if possible
- Never enters the space
 

### Equipment Requirements

- Testing and monitoring equipment
- Ventilation equipment
- Communication equipment
- Personal protective equipment
- Lighting equipment
- Barriers and shields
- Ingress/egress equipment (ladders, etc.)
- Rescue and emergency equipment
 

## Controlling Hazards

### Ventilation

- Most common method to control atmospheric hazards
- Must be continuous unless unfeasible
- Direct air to work areas
- Don't recirculate contaminated air
- Provide at least 10,000 cfm for most spaces
- Allow sufficient time before entry
- Verify effectiveness with testing
 

### Isolation

- Locking out electrical sources
- Blanking or blinding piping
- Misaligning or removing sections of lines or pipes
- Double block and bleed system
- Machine guarding
- Blocking or disconnecting mechanical linkages
 

### Personal Protective Equipment

- Respiratory protection appropriate for hazards
- Chemical-resistant gloves and clothing
- Eye and face protection
- Head protection
- Hearing protection
- Fall protection if needed
- Never substitute PPE for engineering controls
 

## Rescue and Emergency Services

### Types of Rescue

- **Self-rescue**: Entrant recognizes danger and exits
- **Non-entry rescue**: Retrieval from outside the space
- **Entry rescue**: Trained rescuers enter space
 

### Retrieval Systems

- Required unless they increase risk or won't help
- Full body harness with retrieval line
- Wristlets only if harnesses create greater hazard
- Mechanical retrieval device for vertical spaces deeper than 5 feet
- Attachment point outside space
 

### Rescue Service Requirements

- Respond in timely manner
- Equipped for specific space hazards
- Trained in first aid and CPR
- Practice rescues annually
- Know hazards they may face
- Proficient with rescue equipment
 

### In-House Rescue Teams

- Properly equipped for all confined spaces
- Trained to perform assigned rescue functions
- Practice rescue at least once every 12 months
- Trained in basic first aid and CPR
- All members current in certifications
 

## Training Requirements

### Who Needs Training

- All workers involved in confined space work
- Entry supervisors
- Authorized entrants
- Attendants
- Rescue team members
- Testing/monitoring personnel
 

### What Training Must Cover

- Hazards of confined spaces
- Control methods
- Duties of each role
- Entry procedures
- Permit system
- Equipment use
- Rescue procedures
- Emergency response
 

### When Training Is Required

- Before first assignment
- Before change in duties
- When new hazards arise
- When procedures change
- When performance shows deficiencies
- When regulations change
 

## Alternative Procedures

### When Alternative Procedures Apply

- Only hazard is atmospheric
- Ventilation alone controls the hazard
- Monitoring verifies safe atmosphere
- Entry through limited or restricted opening
 

### Required Steps

- Eliminate hazards before entry
- Continuous forced air ventilation
- Periodic atmospheric testing
- Written certification procedure
- Entrants can exit quickly
- No work that introduces hazards
 

## Special Considerations

### Hot Work in Confined Spaces

- Requires special permit
- Additional ventilation requirements
- Fire watch
- Specialized PPE
- Continuous monitoring
- Remove flammable materials
 

### Sewer Systems

- Continuous monitoring required
- Flow control/isolation needed
- Protection from biological hazards
- Specialized rescue procedures
- Protection from vehicle traffic above
 

### Construction-Specific Hazards

- Newly created spaces change conditions
- Multiple contractors working in/around spaces
- Changing conditions during work
- Materials being introduced
- Power tools creating additional hazards
- Temporary electrical installations
 

## Communication and Coordination

### Multi-employer Worksites

- Host employer provides information about spaces
- Controlling contractor coordinates entry operations
- Entry employers follow permit procedures
- All must communicate hazards to each other
- Debrief after entry operations
 

### Information Exchange Requirements

- Location of permit spaces
- Hazards identified
- Precautions taken previously
- Classification of spaces
- Documentation of decisions