# Electrical Safety for Construction Workers

Source: https://usi.how/osha-10-construction/electrical-safety-for-construction-workers

## Electrical Hazards on Construction Sites

Electricity can injure or kill in several ways:

### Electric Shock

- Happens when current travels through your body
- As little as 10 milliamps can cause painful shock
- 100 milliamps can be fatal
- Severity depends on amount of current, path through body, and duration
 

### Arc Flash/Blast

- Explosive release of energy
- Can cause severe burns, blindness, hearing damage
- Can throw workers across rooms
- Can ignite clothing and cause fires
 

### Fire

- Faulty wiring or overloaded circuits
- Damaged insulation
- Improper use of equipment
- Combustible materials near heat sources
 

### Falls

- Often result from shock or startling
- Secondary injury after electrical contact
- Can be more serious than the shock itself
 

## Common Electrical Hazards

### Overhead Power Lines

- Leading cause of electrical fatalities
- Always assume lines are energized
- Maintain at least 10 feet distance (more for higher voltages)
- Use spotters when operating equipment near lines
 

### Damaged Tools and Equipment

- Cracked casings
- Damaged cords or plugs
- Missing grounding pins
- Exposed wiring
 

### Improper Grounding

- Missing ground pins
- Improper wiring
- Using two-prong adapters on three-prong tools
 

### Wet Conditions

- Water greatly increases electrical hazards
- Never use electric tools in wet locations unless specifically designed for it
- Keep cords and equipment away from water
 

### Overloaded Circuits

- Too many devices on one circuit
- Can cause overheating, fires, and equipment damage
- Use proper gauge extension cords for the amperage needed
 

## Safe Work Practices

### Before Work Begins

- Identify all electrical hazards in the work area
- Locate and identify utilities before digging
- Ensure all workers are trained on electrical hazards
- Plan work to avoid electrical dangers
 

### When Using Electrical Equipment

- Inspect all tools and cords before use
- Don't use damaged equipment - tag it and remove from service
- Keep cords away from heat, oil, and sharp edges
- Don't carry tools by their cords
- Disconnect tools when not in use
 

### Extension Cords

- Use the right cord for the job (gauge, length, indoor/outdoor rating)
- Don't remove ground pins or use adapters
- Don't run cords through doorways, windows, or holes without protection
- Don't use staples or nails to secure cords
- Uncoil cords completely when in use
 

### Working Near Power Lines

- Maintain proper clearance (at least 10 feet for most voltages)
- Use non-conductive ladders (fiberglass) near electricity
- Have power lines de-energized when possible
- Use warning signs and barriers around overhead lines
 

### Temporary Power

- Use GFCI protection
- Protect temporary wiring from damage
- Route cords overhead when possible
- Use weatherproof boxes and connections outdoors
 

## Ground Fault Circuit Interrupters (GFCIs)

- **Required** on all construction sites for temporary power
- Cuts power when it detects current leakage
- Test GFCIs before each use with the "Test" button
- Can save your life by preventing electrocution
- Available as outlets, extension cords, or plug-in devices
 

## Lockout/Tagout Procedures

When working on electrical equipment:

1. Turn off the power
2. Disconnect the equipment from power source
3. Apply a lock to prevent others from turning power back on
4. Apply a tag identifying who locked it and why
5. Verify the equipment is de-energized by trying to turn it on
6. Complete the work
7. Remove locks and tags when work is finished
 

## If Someone Is Being Shocked

- Don't touch them - you could be shocked too
- Turn off the power source immediately
- Use a non-conductive object to separate victim from source if necessary
- Call for emergency help
- Provide first aid if trained to do so